PLANOFLEX(NGFLGOEU-J power cables7×25300/500 V
PLANOFLEX(NGFLGOEU-J power cables7×35300/500 V
PLANOFLEX(NGFLGOEU-J power cables7×4300/500 V
PLANOFLEX(NGFLGOEU-J power cables7×6300/500 V
PROTOMONT NSSHÖU 0.6/1 kV1×1200,6/1 kV
PROTOMONT NSSHÖU 0.6/1 kV1×1500,6/1 kV
PROTOMONT NSSHÖU 0.6/1 kV1×160,6/1 kV
PROTOMONT NSSHÖU 0.6/1 kV1×1850,6/1 kV
PROTOMONT NSSHÖU 0.6/1 kV1×2400,6/1 kV
PROTOMONT NSSHÖU 0.6/1 kV1×250,6/1 kV
PROTOMONT NSSHÖU 0.6/1 kV1×3000,6/1 kV
PROTOMONT NSSHÖU 0.6/1 kV1×350,6/1 kV
PROTOMONT NSSHÖU 0.6/1 kV1×500,6/1 kV
PROTOMONT NSSHÖU 0.6/1 kV1×700,6/1 kV
PROTOMONT NSSHÖU 0.6/1 kV1×950,6/1 kV
PROTOMONT NSSHÖU 0.6/1 kV10×1.50,6/1 kV
PROTOMONT NSSHÖU 0.6/1 kV10×2.50,6/1 kV
PROTOMONT NSSHÖU 0.6/1 kV12×2.50,6/1 kV
PROTOMONT NSSHÖU 0.6/1 kV12×40,6/1 kV
PROTOMONT NSSHÖU 0.6/1 kV14×2.50,6/1 kV
PROTOMONT NSSHÖU 0.6/1 kV14×40,6/1 kV
PROTOMONT NSSHÖU 0.6/1 kV18×2.50,6/1 kV
PROTOMONT NSSHÖU 0.6/1 kV2×1.50,6/1 kV
PROTOMONT NSSHÖU 0.6/1 kV2×2.50,6/1 kV
PROTOMONT NSSHÖU 0.6/1 kV2×40,6/1 kV
PROTOMONT NSSHÖU 0.6/1 kV24×1.50,6/1 kV
PROTOMONT NSSHÖU 0.6/1 kV24×2.50,6/1 kV
PROTOMONT NSSHÖU 0.6/1 kV3×1.50,6/1 kV
PROTOMONT NSSHÖU 0.6/1 kV3×1.50,6/1 kV
PROTOMONT NSSHÖU 0.6/1 kV3×100,6/1 kV

Product details


XYMM-J 4 × 2.5 mm² 450/750 V

Product category: insulated and sheathed wires
Type: XYMM-J
Rated voltage: 450/750 V
Conductor material: CU
No. of cores: 4
Cross-section: 2.5 mm²
Core insulation material: PVC
Outer jacket material: PVC
Nominal outer diameter: 13.0 mm
Approx. weight: 230 kg/km
Delivery length: 100 m
500 m
1000 m
Construction: Fine stranded copper wirde acc. Class 5, Insulation: cold resistant PVC, conductors stranded, outer sheath: cold resistant PVC
Standard: ÖVE K41
Available colours: yellow
Leadfree
Minimum installation temperature: -5°C
Application: In dry and humid places and outdoors, for medial and heavy mechanical stress, at low temperatures especially in the area of constructions and temporary appliances, explosive areas. Permitted temperature at cable surface: max. +70 °C for installation and handling min. -35 °C cold resistand not in operation up to -40°C

Data sheet