Disclaimer: By using this website, you agree to the Terms and Conditions of Use (last updated 10/31/15).

View document Print document

×

Search by parameters


You can specify any of the following parameters.

Hold CTRL to select multiple options or de-select options in a filter.


Search results


2768 products match the given parameters.

Alphabetical filter

All 0-9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z


CYKY7×4450/750 V
CYYpl2×1.5450/750 V
CYYpl2×2.5450/750 V
CYYpl3×1.5450/750 V
CYYpl3×2.5450/750 V
DFC - Duplex Fibre Drop Cable 2F
Dielectric Armoured Optical Cables 12F (1 x 12F)
Dielectric Armoured Optical Cables 144F (12 x 12F)
Dielectric Armoured Optical Cables 192F (16 x 12F)
Dielectric Armoured Optical Cables 24F (2 x 12F)
Dielectric Armoured Optical Cables 288F (24 x 12F)
Dielectric Armoured Optical Cables 36F (3 x 12F)
Dielectric Armoured Optical Cables 48F (4 x 12F)
Dielectric Armoured Optical Cables 60F (5 x 12F)
Dielectric Armoured Optical Cables 72F (6 x 12F)
Dielectric Armoured Optical Cables 96F (8 x 12F)
Direct Buried Glass yarn Armoured 12F (1 x 12F)
Direct Buried Glass yarn Armoured 144F (12 x 12F)
Direct Buried Glass yarn Armoured 192F (16 x 12F)
Direct Buried Glass yarn Armoured 24F (2 x 12F)
Direct Buried Glass yarn Armoured 288F (24 x 12F)
Direct Buried Glass yarn Armoured 36F (3 x 12F)
Direct Buried Glass yarn Armoured 48F (4 x 12F)
Direct Buried Glass yarn Armoured 60F (5 x 12F)
Direct Buried Glass yarn Armoured 72F (6 x 12F)
Direct Buried Glass yarn Armoured 96F (8 x 12F)
Direct buried STA 12F (1 x 12F)
Direct buried STA 144F (12 x 12F)
Direct buried STA 192F (16 x 12F)
Direct buried STA 24F (2 x 12F)

Product details


H07RN-F 4 × 1.5 mm² 450/750 V

Product category: insulated and sheathed wires
Type: H07RN-F
Rated voltage: 450/750 V
Conductor material: CU
No. of cores: 4
Cross-section: 1.5 mm²
Conductor structure: Class 5
Core insulation material: EPR
Outer jacket material: CPE
Nominal outer diameter: 10.7 mm
Approx. weight: 166 kg/km
Resistant to…: oil
Appplication: indoor/outdoor
Delivery length: 100 m
500 m
1000 m
Construction: Conductor: Flexible bare copper (Class 5), round shape, finely stranded EN 60228. Insulation: Cross-linked rubber compound (EPR) EI4 acording to EN 50363-1. Assembly: Cores layed-up together. Outer sheath: Cross-linked polychloroprene rubber compound (CPE) EM2 according to EN 50363-2-1. Marking: Clause 6 of EN 50525-1
Standard: EN 50525-2-21 [CPR E]
Available colours: black
Fire performance: Flame retardant - EN 60332-1-2
Leadfree
UV resistant
Minimum installation temperature: Fix installation -40°C. Flexible installation -25°C
Application: H07RN-F cables are suitable for use in dry, humid or moist rooms and outdoor for transportable motors or machines on building sites or in agricultural works. Medium mechanical stresses, e.g. for industrial and agricultural workshop appliances, large boiling installations, heating plates, inspection lamps, electric tools such as drills, circular saws, domestic electric tools. Can be used in workshops having an explosive atmosphere. When a cable is used in the presence of explosive or flammable at

Data sheet