Disclaimer: By using this website, you agree to the Terms and Conditions of Use (last updated 10/31/15).

View document Print document

×

Search by parameters


You can specify any of the following parameters.

Hold CTRL to select multiple options or de-select options in a filter.


Search results


2768 products match the given parameters.

Alphabetical filter

All 0-9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z


SIENOPYR(120) (N)HX4GAF 0.6/1kV1×40,6/1 kV
SIENOPYR(120) (N)HX4GAF 0.6/1kV1×500,6/1 kV
SIENOPYR(120) (N)HX4GAF 0.6/1kV1×60,6/1 kV
SIENOPYR(120) (N)HX4GAF 0.6/1kV1×700,6/1 kV
SIENOPYR(120) (N)HX4GAF 0.6/1kV1×950,6/1 kV
SIENOPYR-PLUS E30 JE-H(St)H FE18012×2x0.8
SIENOPYR-PLUS E30 JE-H(St)H FE18012×2x0.8
SIENOPYR-PLUS E30 JE-H(St)H FE18016×2x0.8
SIENOPYR-PLUS E30 JE-H(St)H FE18016×2x0.8
SIENOPYR-PLUS E30 JE-H(St)H FE1802×2x0.8
SIENOPYR-PLUS E30 JE-H(St)H FE1802×2x0.8
SIENOPYR-PLUS E30 JE-H(St)H FE18020×2x0.8
SIENOPYR-PLUS E30 JE-H(St)H FE18020×2x0.8
SIENOPYR-PLUS E30 JE-H(St)H FE18024×2x0.8
SIENOPYR-PLUS E30 JE-H(St)H FE18024×2x0.8
SIENOPYR-PLUS E30 JE-H(St)H FE18032×2x0.8
SIENOPYR-PLUS E30 JE-H(St)H FE18032×2x0.8
SIENOPYR-PLUS E30 JE-H(St)H FE1804×2x0.8
SIENOPYR-PLUS E30 JE-H(St)H FE1804×2x0.8
SIENOPYR-PLUS E30 JE-H(St)H FE18040×2x0.8
SIENOPYR-PLUS E30 JE-H(St)H FE18040×2x0.8
SIENOPYR-PLUS E30 JE-H(St)H FE18052×2x0.8
SIENOPYR-PLUS E30 JE-H(St)H FE18052×2x0.8
SIENOPYR-PLUS E30 JE-H(St)H FE1808×2x0.8
SIENOPYR-PLUS E30 JE-H(St)H FE1808×2x0.8
SIENOPYR-PLUS E30 JE-H(St)H FE18080×2x0.8
SINOTHERM (110) H07G-K1×1.5450/750 V
SINOTHERM (110) H07G-K1×10450/750 V
SINOTHERM (110) H07G-K1×120450/750 V
SINOTHERM (110) H07G-K1×150450/750 V

Product details


Dielectric Armoured Optical Cables 72F (6 x 12F)

Product category: indoor cables
Type: Dielectric Armoured Optical Cables 72F (6 x 12F)
Conductor material: Optical fibre
Armouring: Glass yarns
Outer jacket material: HFFR
Nominal outer diameter: 12.0 mm
Approx. weight: 145 kg/km
Appplication: indoor/outdoor
Delivery length: 4000 m
Construction: Central Strength Member (CSM). Loose Tube containing fibres and filled with a suitable water tightness compound. Loose tubes SZ stranded around the CSM. Longitudinal Water Tightness: dry core with water swellable elements. Peripheral strength elements and non metallic armour: glass yarns. Ripcords. Outer Sheath: black HFFR.
Standard: IEC 60794; IEC 60793 ; IEC 60332-1; IEC 61034; IEC 60754; ITU-T Rec. G.650; ITU-T Rec. G.652; ITU-T Rec. G.655; ITU-T Rec. G.656; ITU-T Rec. G.657
Leadfree
Minimum installation temperature: -40°C to +70°C
Application: Indoor/outdoor installation. Suitable for installation in buildings and tunnel backbones with high lightning risks, exposure to high voltage and rodent presence, where zero halogen and low smoke are required. Those cables may be installed as well in the outside plant as inside buildings.

Data sheet