Disclaimer: By using this website, you agree to the Terms and Conditions of Use (last updated 10/31/15).

View document Print document

×

Search by parameters


You can specify any of the following parameters.

Hold CTRL to select multiple options or de-select options in a filter.


Search results


2768 products match the given parameters.

Alphabetical filter

All 0-9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z


PLANOFLEX(NGFLGOEU-J power cables7×25300/500 V
PLANOFLEX(NGFLGOEU-J power cables7×35300/500 V
PLANOFLEX(NGFLGOEU-J power cables7×4300/500 V
PLANOFLEX(NGFLGOEU-J power cables7×6300/500 V
PROTOMONT NSSHÖU 0.6/1 kV1×1200,6/1 kV
PROTOMONT NSSHÖU 0.6/1 kV1×1500,6/1 kV
PROTOMONT NSSHÖU 0.6/1 kV1×160,6/1 kV
PROTOMONT NSSHÖU 0.6/1 kV1×1850,6/1 kV
PROTOMONT NSSHÖU 0.6/1 kV1×2400,6/1 kV
PROTOMONT NSSHÖU 0.6/1 kV1×250,6/1 kV
PROTOMONT NSSHÖU 0.6/1 kV1×3000,6/1 kV
PROTOMONT NSSHÖU 0.6/1 kV1×350,6/1 kV
PROTOMONT NSSHÖU 0.6/1 kV1×500,6/1 kV
PROTOMONT NSSHÖU 0.6/1 kV1×700,6/1 kV
PROTOMONT NSSHÖU 0.6/1 kV1×950,6/1 kV
PROTOMONT NSSHÖU 0.6/1 kV10×1.50,6/1 kV
PROTOMONT NSSHÖU 0.6/1 kV10×2.50,6/1 kV
PROTOMONT NSSHÖU 0.6/1 kV12×2.50,6/1 kV
PROTOMONT NSSHÖU 0.6/1 kV12×40,6/1 kV
PROTOMONT NSSHÖU 0.6/1 kV14×2.50,6/1 kV
PROTOMONT NSSHÖU 0.6/1 kV14×40,6/1 kV
PROTOMONT NSSHÖU 0.6/1 kV18×2.50,6/1 kV
PROTOMONT NSSHÖU 0.6/1 kV2×1.50,6/1 kV
PROTOMONT NSSHÖU 0.6/1 kV2×2.50,6/1 kV
PROTOMONT NSSHÖU 0.6/1 kV2×40,6/1 kV
PROTOMONT NSSHÖU 0.6/1 kV24×1.50,6/1 kV
PROTOMONT NSSHÖU 0.6/1 kV24×2.50,6/1 kV
PROTOMONT NSSHÖU 0.6/1 kV3×1.50,6/1 kV
PROTOMONT NSSHÖU 0.6/1 kV3×1.50,6/1 kV
PROTOMONT NSSHÖU 0.6/1 kV3×100,6/1 kV

Product details


ADSS Flextube® 144F (12 x 12F)

Product category: aerial cables
Type: ADSS Flextube® 144F (12 x 12F)
Conductor material: Optical fibre
Outer jacket material: PE
Nominal outer diameter: 13.4 mm
Approx. weight: 135 kg/km
Resistant to…: UV
Appplication: aerial
Delivery length: 4000 m
Construction: Flextube® housing the fibres. Water tightness with dry elements. Dielectric reinforcement. PE outer sheath, black, with radial dielectric strength members
Standard: IEC 60794; IEC 60793; ITU-T Rec. G.650; ITU-T Rec. G.657; ITU-T Rec. G.652
Leadfree
UV resistant
Minimum installation temperature: -30°C to +70°C
Application: Aerial installation between poles, up to 80m span. When ordered for FTTx networks, BendBrightXS fibre provides the lowest attenuation at 1625nm after installation and splicing with miniaturized equipments. The Flextube® design provides easier storage & faster installation. Finger access to the fibres : no specific tools to open the Flextube. Cable must be installed with qualified fittings.

Data sheet