Disclaimer: By using this website, you agree to the Terms and Conditions of Use (last updated 10/31/15).

View document Print document

×

Search by parameters


You can specify any of the following parameters.

Hold CTRL to select multiple options or de-select options in a filter.


Search results


2768 products match the given parameters.

Alphabetical filter

All 0-9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z


PLANOFLEX NGFLGOEU-J Control cables12×1.5300/500 V
PLANOFLEX NGFLGOEU-J Control cables12×2.5300/500 V
PLANOFLEX NGFLGOEU-J Control cables24×1.5300/500 V
PLANOFLEX NGFLGOEU-J Control cables24×2.5300/500 V
PLANOFLEX NGFLGOEU-J Control cables3×1.5300/500 V
PLANOFLEX NGFLGOEU-J Control cables4×1.5300/500 V
PLANOFLEX NGFLGOEU-J Control cables4×2.5300/500 V
PLANOFLEX NGFLGOEU-J Control cables42×1.5300/500 V
PLANOFLEX NGFLGOEU-J Control cables5×1.5300/500 V
PLANOFLEX NGFLGOEU-J Control cables5×2.5300/500 V
PLANOFLEX NGFLGOEU-J Control cables7×1.5300/500 V
PLANOFLEX NGFLGOEU-J Control cables7×2.5300/500 V
PLANOFLEX NGFLGOEU-J Control cables8×1.5300/500 V
PLANOFLEX NGFLGOEU-J Control cables8×2.5300/500 V
PLANOFLEX(NGFLGOEU-J power cables4×10300/500 V
PLANOFLEX(NGFLGOEU-J power cables4×120300/500 V
PLANOFLEX(NGFLGOEU-J power cables4×16300/500 V
PLANOFLEX(NGFLGOEU-J power cables4×25300/500 V
PLANOFLEX(NGFLGOEU-J power cables4×35300/500 V
PLANOFLEX(NGFLGOEU-J power cables4×4300/500 V
PLANOFLEX(NGFLGOEU-J power cables4×50300/500 V
PLANOFLEX(NGFLGOEU-J power cables4×6300/500 V
PLANOFLEX(NGFLGOEU-J power cables4×70300/500 V
PLANOFLEX(NGFLGOEU-J power cables4×95300/500 V
PLANOFLEX(NGFLGOEU-J power cables5×10300/500 V
PLANOFLEX(NGFLGOEU-J power cables5×16300/500 V
PLANOFLEX(NGFLGOEU-J power cables5×4300/500 V
PLANOFLEX(NGFLGOEU-J power cables5×6300/500 V
PLANOFLEX(NGFLGOEU-J power cables7×10300/500 V
PLANOFLEX(NGFLGOEU-J power cables7×16300/500 V

Product details


ADSS HT 72F (6 x 12F)

Product category: aerial cables
Type: ADSS HT 72F (6 x 12F)
Conductor material: Optical fibre
Outer jacket material: PE
Nominal outer diameter: 16.2 mm
Approx. weight: 220 kg/km
Resistant to…: UV
Appplication: aerial
Delivery length: 4000 m
Construction: Central Strength Member (CSM). Loose Tube containing fibres and filled with a suitable water tightness compound. Loose tubes SZ stranded around the CSM. Longitudinal Water Tightness: dry core with water swellable elements. Inner Sheath: PE. Ripcords underneath the sheath. Peripheral Strength Elements: aramid yarns. Ripcords. Outer Sheath: tracking resistant compound. Black. (1) The outer sheath is tracking resistant up to 25kV according to specification IEEE P 1222 §3.7 Class B, Test requirement
Standard: IEC 60794; IEC 60793; IEEE 1222 ; ITU-T Rec. G.650; ITU-T Rec. G.652 ; ITU-T Rec. G.655 ; ITU-T Rec. G.656 ; ITU-T Rec. G.657
Leadfree
UV resistant
Minimum installation temperature: -40°C to +70°C
Application: Installation in aerial, up to 800m span. ADSS (All Dielectric Self Supported) cables are designed for aerial installations, especially for use in electrical power lines. As this cable design does not contain any metallic elements and have sheath protection against tracking effect, it could be installed on medium and high voltage lines. Unaffected by electromagnetic fields, ADSS cables can be installed and maintained on extra high-voltage power lines without interruption of power service to custo

Data sheet