Disclaimer: By using this website, you agree to the Terms and Conditions of Use (last updated 10/31/15).

View document Print document

×

Search by parameters


You can specify any of the following parameters.

Hold CTRL to select multiple options or de-select options in a filter.


Search results


2768 products match the given parameters.

Alphabetical filter

All 0-9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z


PLANOFLEX(NGFLGOEU-J power cables7×25300/500 V
PLANOFLEX(NGFLGOEU-J power cables7×35300/500 V
PLANOFLEX(NGFLGOEU-J power cables7×4300/500 V
PLANOFLEX(NGFLGOEU-J power cables7×6300/500 V
PROTOMONT NSSHÖU 0.6/1 kV1×1200,6/1 kV
PROTOMONT NSSHÖU 0.6/1 kV1×1500,6/1 kV
PROTOMONT NSSHÖU 0.6/1 kV1×160,6/1 kV
PROTOMONT NSSHÖU 0.6/1 kV1×1850,6/1 kV
PROTOMONT NSSHÖU 0.6/1 kV1×2400,6/1 kV
PROTOMONT NSSHÖU 0.6/1 kV1×250,6/1 kV
PROTOMONT NSSHÖU 0.6/1 kV1×3000,6/1 kV
PROTOMONT NSSHÖU 0.6/1 kV1×350,6/1 kV
PROTOMONT NSSHÖU 0.6/1 kV1×500,6/1 kV
PROTOMONT NSSHÖU 0.6/1 kV1×700,6/1 kV
PROTOMONT NSSHÖU 0.6/1 kV1×950,6/1 kV
PROTOMONT NSSHÖU 0.6/1 kV10×1.50,6/1 kV
PROTOMONT NSSHÖU 0.6/1 kV10×2.50,6/1 kV
PROTOMONT NSSHÖU 0.6/1 kV12×2.50,6/1 kV
PROTOMONT NSSHÖU 0.6/1 kV12×40,6/1 kV
PROTOMONT NSSHÖU 0.6/1 kV14×2.50,6/1 kV
PROTOMONT NSSHÖU 0.6/1 kV14×40,6/1 kV
PROTOMONT NSSHÖU 0.6/1 kV18×2.50,6/1 kV
PROTOMONT NSSHÖU 0.6/1 kV2×1.50,6/1 kV
PROTOMONT NSSHÖU 0.6/1 kV2×2.50,6/1 kV
PROTOMONT NSSHÖU 0.6/1 kV2×40,6/1 kV
PROTOMONT NSSHÖU 0.6/1 kV24×1.50,6/1 kV
PROTOMONT NSSHÖU 0.6/1 kV24×2.50,6/1 kV
PROTOMONT NSSHÖU 0.6/1 kV3×1.50,6/1 kV
PROTOMONT NSSHÖU 0.6/1 kV3×1.50,6/1 kV
PROTOMONT NSSHÖU 0.6/1 kV3×100,6/1 kV

Product details


SIENOPYR(120) (N)HX4GAF 0.6/1kV 1 × 95 mm² 0,6/1 kV

Product category: low voltage cables
Type: SIENOPYR(120) (N)HX4GAF 0.6/1kV
Rated voltage: 0,6/1 kV
Conductor material: CU
No. of cores: 1
Cross-section: 95 mm²
Core insulation material: LSOH
Nominal outer diameter: 15.5 mm
Approx. weight: 830 kg/km
Resistant to…: heat
Appplication: railway
Construction: Copper conductor, tinned, finely stranded class 5 according to DIN VDE 0295 / IEC 60228. Insulation halogen-free, heat resistant, cross-linked elastomeric special compound, requirements based on type EI 109
Standard: DIN EN 50264-3-1
Available colours: black, green-yellow
Fire performance: Flame propagation single cable acc. to DIN EN 60332-1-2 bunched cables acc. to DIN EN 50266-2-4 and DIN EN 50305
Leadfree
Halogen-free
Minimum installation temperature: -40°C
Application: Halogen-free single core cables, unsheathed,for railway rolling stock, having special fire performance, increased heat resistance and reduced dimensions. These cables are intented for use in railway rolling stock as fixed wiring, or wiring where limited flexing in operation is encountered. Extra oil and fuel resistance DIN EN 60811-2-1