Standard Flextube cable 144F (12 x 12F) | ||||
Standard Flextube cable 288F (24 x 12F) | ||||
Standard Flextube cable 72F (6 x 12F) | ||||
VertiCasa 12 ESFU | ||||
VertiCasa 24 ESFU | ||||
VertiCasa 36 ESFU | ||||
VertiCasa 48 ESFU |
Produktkategorie: | Niederspannungskabel |
---|---|
Typ: | PROTOMONT NSSHÖU 0.6/1 kV |
Nennspannung: | 0,6/1 kV |
Leitermaterial: | CU |
Aderzahl: | 4 |
Leiterquerschnitt: | 120 mm² |
Isoliermaterial: | EPR |
Mantelmaterial: | CPE |
Außendurchmesser: | 58,6 mm |
Gewicht: | 6758 kg/km |
Beständig gegen: | water |
Verwendung: | indoor/outdoor |
Aufbau: | Kupferleiter, rund, verzinnt, feindrähtig nach DIN EN 60228 Klasse 5, Isolierung Ethylen-Propylen-Gummi (EPR), Außenmantel Synthetischer Kautschuk. |
Normen: | DIN VDE 0250-812 |
Farben: | gelb |
Flammwidrig: | Brandfortleitung nach DIN EN 60332-1-1 und DIN EN 60332-1-2 |
Bleifrei | |
UV - beständig | |
Tiefste Verlegetemperatur: | -40°C |
Anwendung: | PROTOMONT-Gummischlauchleitungen NSSHÖU sind bestimmt für den beweglichen Anschluss von schweren Elektrogeräten im Tagebau und in Steinbrüchen nach DIN VDE 0168 sowie im Bergbau unter Tage nach DIN VDE 0118, auf Baustellen, in gewerblichen und landwirtschaftlichen betrieben bei sehr hohen mechanischen Beanspruchungen. |
Parameter | Value |
---|---|
locale |
de |
id |
NULL
|
alpha |
0 |
details |
32143 |
vp-page |
13 |
Matched? | Class | Mask | Defaults | Module | Request |
---|---|---|---|---|---|
no | Route |
admin/<presenter>/<action=default>/<id> |
module = admin |
|
|
no | Route |
[<locale>/]user/<presenter>/<action>/<id> |
module = user |
|
|
yes | Route |
[<locale>/]<presenter>/<action>/<id> |
module = front |
|
front:search:default |
no identity
Time ms | SQL Statement | Params | Rows | ||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
13,036 explain ► | SELECT `id`, `name`, `cores`, `cross_section`, `voltage` FROM `dnb_catalogue_item` WHERE (`locale` = ?) AND (`name` REGEXP "^([^ ]+ )*[^0-9a-z]*[0-9]") ORDER BY `name`, `cores`, `cross_section`, `voltage`
| "DE" (2)
| 367 | ||||||||||||||||||||
0,646 explain ► | SELECT `id`, `group_id`, `name`, `cores`, `cross_section`, `voltage`, `core_material`, `conductor_1`, `reduced_0`, `conductor_2`, `core_insulation`, `conductor_screen`, `armouring`, `outer_jacket`, `outer_diameter`, `weight`, `resistance_to`, `application`, `delivery_length_1`, `delivery_length_2`, `delivery_length_3` FROM `dnb_catalogue_item` WHERE (`id` = ?)
| "32143" (5)
| 1 | ||||||||||||||||||||
0,526 explain ► | SELECT `id`, `group_id`, `locale`, `appendices`, `picture`, `category`, `construction`, `standard`, `colours`, `fire_performance`, `leadfree`, `halogene_free`, `uv_resistant`, `min_temperature`, `group_application`, `name` FROM `dnb_catalogue_group` WHERE (`group_id` = ?) AND (`locale` = ?) LIMIT 1
| 121
"DE" (2)
| 1 | ||||||||||||||||||||
0,534 explain ► | SELECT `id`, `group_id`, `locale`, `appendices`, `picture`, `category`, `construction`, `standard`, `colours`, `fire_performance`, `leadfree`, `halogene_free`, `uv_resistant`, `min_temperature`, `group_application`, `name` FROM `dnb_catalogue_group` WHERE (`group_id` = ?) AND (`locale` = ?) LIMIT 1
| 121
"EN" (2)
| 1 | ||||||||||||||||||||
1,665 | UPDATE dnb_catalogue_item SET views = views + 1 WHERE id = ?/var/www/clients/client373/web726/web/app/model/CatalogueRepository.php | "32143" (5)
| 1 | ||||||||||||||||||||
68,255 explain ► | SELECT DISTINCT `voltage` FROM `dnb_catalogue_item` WHERE (`locale` = ?)
| "DE" (2)
| 12 | ||||||||||||||||||||
84,236 explain ► | SELECT DISTINCT `core_material` FROM `dnb_catalogue_item` WHERE (`locale` = ?)
| "DE" (2)
| 3 | ||||||||||||||||||||
89,490 explain ► | SELECT DISTINCT `cores` FROM `dnb_catalogue_item` WHERE (`locale` = ?)
| "DE" (2)
| 36 | ||||||||||||||||||||
99,867 explain ► | SELECT DISTINCT `cross_section` FROM `dnb_catalogue_item` WHERE (`locale` = ?)
| "DE" (2)
| 27 | ||||||||||||||||||||
105,169 explain ► | SELECT DISTINCT `core_insulation` FROM `dnb_catalogue_item` WHERE (`locale` = ?)
| "DE" (2)
| 12 | ||||||||||||||||||||
98,738 explain ► | SELECT DISTINCT `armouring` FROM `dnb_catalogue_item` WHERE (`locale` = ?)
| "DE" (2)
| 6 | ||||||||||||||||||||
91,313 explain ► | SELECT DISTINCT `outer_jacket` FROM `dnb_catalogue_item` WHERE (`locale` = ?)
| "DE" (2)
| 13 | ||||||||||||||||||||
84,509 explain ► | SELECT DISTINCT `resistance_to` FROM `dnb_catalogue_item` WHERE (`locale` = ?)
| "DE" (2)
| 10 | ||||||||||||||||||||
76,764 explain ► | SELECT DISTINCT `application` FROM `dnb_catalogue_item` WHERE (`locale` = ?)
| "DE" (2)
| 11 | ||||||||||||||||||||
23,268 explain ► | SELECT `id`, `name`, `cores`, `cross_section`, `voltage` FROM `dnb_catalogue_item` WHERE (`locale` = ?) AND (`name` REGEXP "^([^ ]+ )*[^0-9a-z]*[0-9]") ORDER BY `name`, `cores`, `cross_section`, `voltage` LIMIT 7 OFFSET 360
| "DE" (2)
| 7 |